您好,欢迎来到三六零分类信息网!老站,搜索引擎当天收录,欢迎发信息
免费发信息

英国 SOLO 425-001 热探测器测试器 报价

2019/1/17 13:53:57发布350次查看ip:110.87.91.51发布人:zxz15392421852

 英国 SOLO 425-001 热探测器测试器 报价

品牌 SOLO 425-001 型号 SOLO 425-001
是否进口 材质 SOLO 425-001
通讯方式 SOLO 425-001 环境温度 SOLO 425-001℃
环境湿度≤ SOLO 425-001% 可接防区 SOLO 425-001
安装方式 SOLO 425-001 报警模式 其他
适用范围 SOLO 425-001 测量范围 SOLO 425-001
外形尺寸 其他 颜色 其他
工作电压 SOLO 425-001 产地 SOLO 425-001

  英国SOLO 425-001 热探测器测试器 报价

  专业的国际采购员,优势价格,不仅如此,我公司是以空运的方式,在货期上取胜,如果您急需某项进口产品,我们是你非常好的选择,快速的将货物送到您的手中!您的来电是合作的开始。

  Remedial action and records As well as the routine maintenance that we always think about, there is the need to keep the fire alarm system optimised. This depends heavily on the competence of the maintenance technician, and his familiarity with the many issues that can detrimentally affect a fire alarm/detection system. Some of the areas that need consideration are:

  补救措施和记录以及我们一直考虑的日常维护,有必要保持火灾报警系统的优化。这在很大程度上取决于维修技术人员的能力,以及他对许多可能对火灾报警/检测系统产生不利影响的问题的熟悉程度。需要考虑的一些方面包括:

  ● change of use of a room or rooms or whole building

  ● refurbishing/redecoration

  ● building alterations

  ● obstruction of air flow

  ● introduction of hazardous materials

  ● change of tenant

  ● change of escape arrangements

  ● ageing equipment

  ● addition of sound insulation

  ● causes of false alarms

  ● causes of false alarms In addition, there is the general deterioration of pieces of equipment that can occur due to normal operation. For instance, the electrochemical cell used in CO detectors deteriorates at different rates depending on the environment to which it is exposed.

  ●改变一个或多个房间或整个建筑物的使用

  ●翻新/重新装修

  ●建筑改造

  ●气流受阻

  ●危险材料介绍

  ●承租人变更

  ●逃生安排的变更

  ●老化设备

  ●增加隔音材料

  ●错误警报的原因

  ●错误报警的原因。此外,正常运行可能导致设备部件的一般损坏。例如,一氧化碳探测器中使用的电化学电池根据其暴露的环境以不同的速率退化。

  The point about all this is that the fire alarm and detection system is a 'living' system and as such, it needs to be constantly reviewed to make sure it is ready and able to fulfil its purpose. If, for instance, some new offices are installed in an open plan area without detection being installed, a fire could start in one of the offices and would not be detected until it burst out of the room at an already advanced stage of development. This could then result in people being trapped and even killed by having their escape route cut off.

  英国SOLO 425-001 热探测器测试器 报价

  所有这些的要点是,火灾报警和探测系统是一个“活的”系统,因此,需要不断地对其进行审查,以确保其准备就绪并能够实现其目的。例如,如果一些新办公室安装在开放式平面区域,而没有安装检测装置,那么其中一个办公室可能会发生火灾,直到火灾在已经发展的高级阶段从房间中爆发时才会被检测到。这可能导致人们被困,甚至被切断他们的逃生路线杀害。

该用户其它信息

VIP推荐

15392421852
曾经理
 发送短信
免费发布信息,免费发布B2B信息网站平台 - 三六零分类信息网 沪ICP备09012988号-2
企业名录