回收e8363c,现金收购e8363c
产品型号:e8363c
产品品牌:agilent 、hp
产品指标:10 mhz to 40 ghz
详细说明
110 db of dynamic range <0.006 db trace noise
<26 usec/point measurement speed, 32 channels, 20,001 points
trl/lrm calibration, on-wafer, in-fixture, waveguide, and antenna measurements
mixer conversion loss, return loss, isolation, and absolute group delay
amplifier gain compression, harmonic, imd, and pulsed-rf
table 2. receiver dynamic rangea
description specification
(db) at test
portb
typical (db) at direct
receiver access inputc
dynamic range (in a 10 hz bw)
standard configuration and standard power range (e836xb/c - standard)
or
standard configuration and extended power range & bias tees (e836xb/c - option unl)
10 mhz to 45 mhzd 82 (typical) na --
45 mhz to 500 mhze 94 na --
500 mhz to 2 ghz 119 na --
2 ghz to 10 ghz 122 na --
10 ghz to 20 ghz 125 na --
20 ghz to 30 ghz 114 na
30 ghz to 40 ghz 111 na
40 ghz to 50 ghz 111 na
option 016 degrades
performance by 2 db.
configurable test set and standard power range (e836xb/c - option 014)
or
configurable test set and extended power range & bias tees (e836xb/c - option 014/unl)
10 mhz to 45 mhzd 82 (typical) 132 --
45 mhz to 500 mhze 94 132 --
500 mhz to 2 ghz 119 138 --
2 ghz to 10 ghz 122 137 --
10 ghz to 20 ghz 124 139 --
20 ghz to 30 ghz 113 125
30 ghz to 40 ghz 110 122
40 ghz to 50 ghz 109 120
option 016 degrades
performance by 2 db.
a the receiver dynamic range is calculated as the difference between the noise floor and the receiver maximum output power. the effective
dynamic range must take measurement uncertainties and interfering signals into account.
b the test port receiver dynamic range is calculated as the difference between the test port noise floor and the receiver maximum input
level. the effective dynamic range must take measurement uncertainties and interfering signals into account.
c the direct receiver access input receiver dynamic range is calculated as the difference between the direct receiver access input noise floor
and the receiver maximum input level. the effective dynamic range must take measurement uncertainties and interfering signals into
account. this set-up should only be used when the receiver input will never exceed its compression or damage level. when the analyzer is
in segment sweep mode, the analyzer can have predefined frequency segments which will output a higher power level when the extended
dynamic range is required (i.e. devices with high insertion loss), and reduced power when compression or receiver damage may occur (i.e.
devices with low insertion loss). the extended range is only available in one-path transmission measurements.
d typical performance.
e may be degraded by 10 db at particular frequencies (multiples of 5 mhz) below 500 mhz due to spurious receiver residuals. methods are
available to regain the full dynamic range.
note: this e836xb/c document provides technical specifications for the following calibration kits only: 85056a,
85056d, 85056k, 85052b, 85052c, 85052d, 85050b, 85050c, 85050d, 85054b, 85054d, k11644a, p11644a,
r11644a, and the x11644a.
8
table 2 (continued). receiver dynamic rangea
description specification
(db) at test
portb
typical (db) at direct
receiver access inputc
dynamic range (in a 10 hz bw)
standard configuration and standard power range (e836xb/c - standard)
or
standard configuration and extended power range & bias tees (e836xb/c - option unl)
10 mhz to 45 mhzd 82 (typical) na --
45 mhz to 500 mhze 94 na --
500 mhz to 2 ghz 119 na --
2 ghz to 10 ghz 122 na --
10 ghz to 20 ghz 125 na --
20 ghz to 30 ghz 114 na
30 ghz to 40 ghz 111 na
40 ghz to 50 ghz 111 na
option 016 degrades
performance by 2 db.
configurable test set and standard power range (e836xb/c - option 014)
or
configurable test set and extended power range & bias tees (e836xb/c - option 014/unl)
10 mhz to 45 mhzd 82 (typical) 132 --
45 mhz to 500 mhze 94 132 --
500 mhz to 2 ghz 119 138 --
2 ghz to 10 ghz 122 137 --
10 ghz to 20 ghz 124 139 --
20 ghz to 30 ghz 113 125
30 ghz to 40 ghz 110 122
40 ghz to 50 ghz 109 120
option 016 degrades
performance by 2 db.
a the receiver dynamic range is calculated as the difference between the noise floor and the receiver maximum output power. the effective
dynamic range must take measurement uncertainties and interfering signals into account.
b the test port receiver dynamic range is calculated as the difference between the test port noise floor and the receiver maximum input
level. the effective dynamic range must take measurement uncertainties and interfering signals into account.
c the direct receiver access input receiver dynamic range is calculated as the difference between the direct receiver access input noise floor
and the receiver maximum input level. the effective dynamic range must take measurement uncertainties and interfering signals into
account. this set-up should only be used when the receiver input will never exceed its compression or damage level. when the analyzer is
in segment sweep mode, the analyzer can have predefined frequency segments which will output a higher power level when the extended
dynamic range is required (i.e. devices with high insertion loss), and reduced power when compression or receiver damage may occur (i.e.
devices with low insertion loss). the extended range is only available in one-path transmission measurements.
d typical performance.
e may be degraded by 10 db at particular frequencies (multiples of 5 mhz) below 500 mhz due to spurious receiver residuals. methods are
available to regain the full dynamic range.
note: this e836xb/c document provides technical specifications for the following calibration kits only: 85056a,
85056d, 85056k, 85052b, 85052c, 85052d, 85050b, 85050c, 85050d, 85054b, 85054d, k11644a, p11644a,
r11644a, and the x11644a.
9
e8363b/c and e8364b/c corrected system performance with 2.4mm connectors
????????????????????????????????????????????
table 3. 85056a calibration kit
standard configuration and standard power range
(e8363b/c and e8364b/c)
applies to the e8363b/c and e8364b/c analyzers, 85056a (2.4mm) calibration kit, 85133f flexible test port cable set, and a full 2-port
calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
40 ghz
40 to
50 ghz
directivity 42 42 38 36
source match 41 38 33 31
load match 42 42 37 35
reflection tracking ±0.001
+0.02/°c
±0.008
+0.02/°c
±0.020
+0.02/°c
±0.027
+0.03/°c
transmission tracking ±0.010
+0.02/°c
±0.049
+0.02/°c
±0.105
+0.02/°c
±0.170
+0.03/°c
10
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
11
reflection uncertainty (specifications)
12
table 4. 85056a calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e8363b/c and e8364b/c analyzers, 85056a (2.4mm) calibration kit, 85133f flexible test port
cable set, and a full 2-port calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
40 ghz
40 to
50 ghz
directivity 42 42 38 36
source match 41 38 33 31
load match 42 42 37 35
reflection tracking ±0.001
+0.02/°c
±0.008
+0.02/°c
±0.020
+0.02/°c
±0.027
+0.03/°c
transmission tracking ±0.019
+0.02/°c
±0.053
+0.02/°c
±0.109
+0.02/°c
±0.182
+0.03/°c
13
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
14
reflection uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
15
table 5. 85056d calibration kit
standard configuration and standard power range
(e8363b/c and e8364b/c)
applies to the, e8363b/c and e8364b/c analyzers, 85056d (2.4mm) calibration kit, 85133f flexible test port cable set, and a full 2-port
calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
40 ghz
40 to
50 ghz
directivity 42 34 26 26
source match 40 30 24 23
load match 42 33 25 25
reflection tracking ±0.002
+0.02/°c
±0.029
+0.02/°c
±0.079
+0.02/°c
±0.075
+0.03/°c
transmission tracking ±0.011
+0.02/°c
±0.121
+0.02/°c
±0.347
+0.02/°c
±0.462
+0.03/°c
16
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
17
reflection uncertainty (specifications)
18
table 6. 85056d calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e8363b/c and e8364b/c analyzers, 85056d (2.4mm) calibration kit, 85133f flexible test port cable set, and a full 2-port
calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
40 ghz
40 to
50 ghz
directivity 42 34 26 26
source match 40 30 24 23
load match 42 33 25 25
reflection tracking ±0.002
+0.02/°c
±0.029
+0.02/°c
±0.079
+0.02/°c
±0.075
+0.03/°c
transmission tracking ±0.022
+0.02/°c
±0.130
+0.02/°c
±0.365
+0.02/°c
±0.498
+0.03/°c
19
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode,
and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
20
reflection uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode,
and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
21
e8363b/c and e8364b/c corrected system performance with 2.92mm connectors
table 7. 85056k calibration kit
standard configuration and standard power range
(e8363b/c and e8364b/c)
applies to the, e8363b/c and e8364b/c analyzers, 85056k (2.92mm) calibration kit, 85133f flexible test port cable set, and a full 2-port
calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
0.045 to
2 ghz
2 to
20 ghz
20 to
40 ghz
directivity 42 42 40
source match 40 40 35
load match 42 41 38
reflection tracking ±0.018
+0.02/°c
±0.018
+0.02/°c
±0.067
+0.03/°c
transmission tracking ±0.011
+0.02/°c
±0.042
+0.02/°c
±0.089
+0.03/°c
22
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
23
reflection uncertainty (specifications)
24
table 8. 85056k calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e8363b/c and e8364b/c analyzers, 85056k (2.92mm) calibration kit, 85133f flexible test port cable set, and a full 2-port
calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
0.045 to
2 ghz
2 to
20 ghz
20 to
40 ghz
directivity 42 42 40
source match 40 40 35
load match 42 41 38
reflection tracking ±0.018
+0.02/°c
±0.018
+0.02/°c
±0.067
+0.03/°c
transmission tracking ±0.021
+0.02/°c
±0.046
+0.02/°c
±0.094
+0.03/°c
25
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode,
and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
26
reflection uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode,
and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
27
e836xb/c corrected system performance with 3.5mm connectors
????????????????????????????????????????????
table 9. 85052b calibration kit
standard configuration and standard power range
(e836xb/c)
applies to the, e836xb/c analyzers, 85052b (3.5mm) calibration kit, 85131f flexible test port cable set, and a full 2-port calibration. data
and traces above 20 ghz are not applicable to the e8362c. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
26.5 ghz
directivity 48 44 44
source match 40 31 31
load match 48 44 44
reflection tracking ±0.003
+0.02/°c
±0.006
+0.02/°c
±0.006
+0.03/°c
transmission tracking ±0.009
+0.02/°c
±0.088
+0.02/°c
±0.104
+0.03/°c
28
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
29
reflection uncertainty (specifications)
30
table 10. 85052b calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e836xb/c analyzers, 85052b (3.5mm) calibration kit, 85131f flexible test port cable set, and a full 2-port calibration. data
and traces above 20 ghz are not applicable to the e8362c. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
26.5 ghz
directivity 48 44 44
source match 40 31 31
load match 48 44 44
reflection tracking ±0.003
+0.02/°c
±0.006
+0.02/°c
±0.006
+0.03/°c
transmission tracking ±0.017
+0.02/°c
±0.091
+0.02/°c
±0.106
+0.03/°c
31
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch
(e836xb/c - option 014, unl, 016, 080, and 081)
32
reflection uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch
(e836xb/c - option 014, unl, 016, 080, and 081)
33
table 11. 85052c calibration kit
standard configuration and standard power range
(e836xb/c)
applies to the, e836xb/c analyzers, 85052c (3.5mm) calibration kit, 85131f flexible test port cable set, and a full 2-port calibration. data
and traces above 20 ghz are not applicable to the e8362c. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
26.5 ghz
directivity 48 50 50
source match 40 50 50
load match 48 50 50
reflection tracking ±0.003
+0.02/°c
±0.000
+0.02/°c
±0.000
+0.03/°c
transmission tracking ±0.009
+0.02/°c
±0.014
+0.02/°c
±0.018
+0.03/°c
34
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
35
reflection uncertainty (specifications)
36
table 12. 85052c calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e836xb/c analyzers, 85052c (3.5mm) calibration kit, 85131f flexible test port cable set, and a full 2-port calibration. data
and traces above 20 ghz are not applicable to the e8362c. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
26.5 ghz
directivity 48 50 50
source match 40 50 50
load match 48 50 50
reflection tracking ±0.003
+0.02/°c
±0.000
+0.02/°c
±0.000
+0.03/°c
transmission tracking ±0.017
+0.02/°c
±0.016
+0.02/°c
±0.019
+0.03/°c
37
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch
(e836xb/c - option 014, unl, 016, 080, and 081)
38
reflection uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch
(e836xb/c - option 014, unl, 016, 080, and 081)
39
table 13. 85052d calibration kit
standard configuration and standard power range
(e836xb/c)
applies to the, e836xb/c analyzers, 85052d (3.5mm) calibration kit, 85131f flexible test port cable set, and a full 2-port calibration. data
and traces above 20 ghz are not applicable to the e8362c. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
26.5 ghz
directivity 42 36 30
source match 37 28 25
load match 42 36 30
reflection tracking ±0.003
+0.02/°c
±0.008
+0.02/°c
±0.011
+0.03/°c
transmission tracking ±0.014
+0.02/°c
±0.131
+0.02/°c
±0.250
+0.03/°c
40
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
41
reflection uncertainty (specifications)
42
table 14. 85052d calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e836xb/c analyzers, 85052d (3.5mm) calibration kit, 85131f flexible test port cable set, and a full 2-port calibration. data
and traces above 20 ghz are not applicable to the e8362c. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
45 mhz to
2 ghz
2 to
20 ghz
20 to
26.5 ghz
directivity 42 36 30
source match 37 28 25
load match 42 36 30
reflection tracking ±0.003
+0.02/°c
±0.008
+0.02/°c
±0.011
+0.03/°c
transmission tracking ±0.026
+0.02/°c
±0.138
+0.02/°c
±0.261
+0.03/°c
43
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch
(e836xb/c - option 014, unl, 016, 080, and 081)
44
reflection uncertainty (specifications)
* configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch
(e836xb/c - option 014, unl, 016, 080, and 081)
45
e836xb/c corrected system performance with 7mm connectors
table 15. 85050b calibration kit
standard configuration and standard power range
(e836xb/c)
applies to the, e836xb/c analyzers, 85050b (7mm) calibration kit, 85132f flexible test port cable set, and a full 2-port
calibration. also applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
0.045 to
2 ghz
2 to
18 ghz
directivity 52 52
source match 48 41
load match 52 47
reflection tracking ±0.003
+0.02/°c
±0.047
+0.02/°c
transmission tracking ±0.004
+0.02/°c
±0.032
+0.02/°c
46
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
47
reflection uncertainty (specifications)
48
table 16. 85050b calibration kit
fully optioned (e836xb/c - option 014, unl, 016, 080, and 081)
configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset mode, and reference channel
transfer switch
applies to the, e836xb/c analyzers, 85050b (7mm) calibration kit, 85132f flexible test port cable set, and a full 2-port calibration. also
applies to the following condition:
environmental temperature 23° ±3 °c, with <1 °c deviation from calibration temperature
description specification (db)
0.045 to
2 ghz
2 to
18 ghz
directivity 52 52
source match 48 41
load match 52 47
reflection tracking ±0.003
+0.02/°c
±0.047
+0.02/°c
transmission tracking ±0.008
+0.02/°c
±0.034
+0.02/°c
49
note: the following graphs also apply to the “c” model of the analyzers.
transmission uncertainty (specifications)
*configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
50
reflection uncertainty (specifications)
*configurable test set, extended power range & bias-tees, receiver attenuators, frequency offset
mode, and reference channel transfer switch (e836xb/c - option 014, unl, 016, 080, and 081)
深圳市鸿翔仪器有限公司
联系人 :肖桥成【经理】
手机:【1】18806648180 肖生【经理】微信同号
【2】15889556681 肖生【工程师】
我们有***优秀的团队,技术部【维修】,销售部,市场部【行情】
,跟售后服务,能做到、“信誉第一”、“质量第一”、“服务第一”。
选用鸿翔仪器有限公司的优势是:
1,品种齐全,货源充足,存库雄厚,服务快捷,维修能力强。
2、与新购仪器几个月的供货期相比,购买二手仪器的供货期要短的多。
3、在时间就是市场的今天,优势无疑是为明显的。
4、二手仪器的价格便宜,基本为新购仪器价格的20%~50%。在电子技术迅
速发展的今天,仪器的更新也在加快,投资越少则风险越小。
5、为了让您放心地使用我们提供的二手仪器,我们销售的二手仪器可以到
;
1、保修半年至一年不等。
2、可以根据您的要求,将仪器送至计量测试单位进行校准。
3、欢迎来电!上门看货!价格好商量!您的满意是我们的追求!^_^
4、深圳地区及东莞,惠州等地方,可上门送货。
(注):另外我公司长期回收进口仪器
如示波器,网络分析仪,频谱分析仪,电桥,电源,信号源、等高端
进口仪器。
可上门高价回收
本公司长期供应/租赁/维修二手进口仪器
深圳市鸿翔仪器有限公司
肖先生
18806648180
广东 深圳 宝安区 龙华新区观澜大道 玫瑰苑 A2 501室