hd-9000a defibrillator
physicalcharacteristics:
mainunit:portable
dimensions:l130xw460xh410   weight:11kg
technicalspecifications
non-synchronizer:externaldefibrillator
sinewave:monophasictechnology
energy:0、20、50、100、160、250、300、360 joule (nominal at aresistance of 50)
chargingtime:at 360j less than10 sec
paddleoptions:reusableexternal adult paddles(pediatricpaddles integrated)
powersupply:operates from themains(ac)and battery
battery: charge 3.5h tofull ;
full charge to 35 shocks(360joules)
sealed rechargeable 12volt  nimh battery
.powerrequirements.
      (a)  ac powersupply                  110v, 60 hz /220v,50hz  
   (b)vehiclevoltage             dc12v
hd-9000b defi-monitor
physicalcharacteristics:
mainunit:desktop
dimensions:l410xw360xh260
weight:13kg
technicalspecifications   
defibrillator.
      (1) defibrillatortype                    manual, synchronized, asynchronized,   
      (2)  out putwaveform                  monophasictechnology                                                                            
      (3)  energyaccuracy                   ∠+1%
   (4)  energyselection          0、20、50、100、160、250、300、360 joule (nominal at aresistance of 50)
      (5)  chargingtime                     maximum 8 seconds to 360joules
   (6)  standard adult/pediatricpaddles   reusable extermal adultpaddles(pediatric paddles integrated)             
.powerrequirements.
      (a)  ac powersupply                  110v, 60 hz /220v,50 hz  
   (b)vehiclevoltage          dc12v
internalbatterybackup
             (1) batterytype           rechargeable lead-acidbattery
             (2)  chargingtime              time-minimum of 4 hours for fullcharging    
          (3) batterycharging     during ac power supplyoperation of the device.
(4) charging/lowbatteryindication     redled                
(5) battery capacity       100% of thebattery will provide 120 mins of monitoring; and 30 discharges at360 joules.
display
-leddimensions    10’diagonal
-type                 high resolution true-color graphic led
ecg
ecg lead:ⅰ, ⅱ, ⅲ, avr, avl, avf,v1~v6, gnd
s-t segment analysis: -2.0~2.0mv
arrhythmia analysis: yes
protection: with stand 4000vac/50hzvoltage in isolation and work against electrosurgical knife and defibrillation
respiration
measurementmethod: thoracic impedance
nibp
working mode:manual/automatic/stat(5 minutes)
method: automatic oscillation
cuff type:standard adult; optional pediatric/neonatal
temperature
measurementrange 20~45℃
resolution0.1℃
pulseoximetry(spo2)
display:spo2 value, pulse histogram,waveform,pulse
range: 0~99%for adult,pediatric andneonatal patients
probe:standard adult fingerclip
optionalpediatric y-type clip and neonatal wrap
pulserange
pulse range:0-255bpm
standardparameter & configuration
 ecg/resp,/spo2,/temp,/pr,/nibp/defibrillator
optionalparameter
recorder
hd-9000c defi-monitor
physicalcharacteristics:
mainunit:portable
dimensions:l320xw205xh410
weight:9.8kg
technicalspecifications   
defibrillator.
      (1)  defibrillatortype                    manual, synchronized, asynchronized,    
      (2)  out putwaveform                  monophasictechnology                                                                            
      (3)  energyaccuracy               ∠+1%
   (4) energyselection                        0,3,5,7,10,20,30,50,100,200,300,360joule(nominal at a resistance of 50)
      (5)  chargingtime                    maximum8seconds to360joules
   (6) standardadult/pediatric paddles  reusableextermal adult paddles(pediatric paddlesintegrated)            
.powerrequirements.
      (a)  ac powersupply                  110v, 60 hz /220v,50hz  
   (b)vehiclevoltage            dc12v
internalbatterybackup
             (1) batterytype          rechargeablelead-acid battery
             (2)  chargingtime             time-minimum of 4hours for full charging    
         (3)batterycharging      duringac power supply operation of the device.
(4) charging/lowbatteryindication     redled                
(5)batterycapacity       100%of the battery will provide 120 mins of monitoring; and 30discharges at 360 joules.
display
-leddimensions    7’diagonal {155mm*88mm}
-type                 high resolution true-color graphic led
-resolution        480x234
ecg
ecg lead:ⅰ, ⅱ, ⅲ, avr, avl, avf,v1~v6, gnd
s-t segment analysis: -2.0~2.0mv
arrhythmia analysis: yes
protection: with stand 4000vac/50hzvoltage in isolation and work against electrosurgical knife and defibrillation
respiration
measurementmethod: thoracic impedance
nibp
working mode:manual/automatic/stat(5 minutes)
method: automatic oscillation
cuff type:standard adult; optional pediatric/neonatal
temperature
measurementrange 20~45℃
resolution0.1℃
pulseoximetry(spo2)
display:spo2 value, pulse histogram,waveform,pulse
range: 0~99%for adult,pediatric andneonatal patients
probe:standard adult fingerclip
optionalpediatric y-type clip and neonatal wrap
pulserange
pulse range:0-255bpm
standardparameter & configuration
 ecg/resp,/spo2,/temp,/pr,/nibp/defibrillator
optionalparameter
recorder
hd-9000ddefi-monitor
physicalcharacteristics:
mainunit:portable
dimensions:l320xw205xh410
weight:9.5kg
technicalspecifications   
defibrillator.
      (1)  defibrillatortype                    manual, synchronized, asynchronized,    
      (2)  out putwaveform                  monophasic technology                                                                            
      (3)  energyaccuracy               ∠+1%
   (4) energyselection                        0,3,5,7,10,20,30,50,100,200,300,360joule(nominal at a resistance of50)
      (5)  chargingtime                    maximum8seconds to360joules
   (6) standardadult/pediatric paddles  reusableexternal adult paddles(pediatricpaddles integrated)            
.powerrequirements.
      (a)  ac powersupply                  110v, 60 hz /220v,50hz  
   (b)vehiclevoltage            dc12v
internalbatterybackup
             (1) batterytype          rechargeablelead-acid battery
             (2)  chargingtime             time-minimum of 4hours for full charging    
         (3)batterycharging      duringac power supply operation of the device.
(4) charging/lowbatteryindication     redled                
(5)batterycapacity       100%of the battery will provide 120 mins of monitoring; and 30discharges at 360 joules.
display
-leddimensions    7’diagonal {155mm*88mm}
-type                 high resolution true-color graphic led
-resolution        480x234
ecg
ecg lead:ⅰ, ⅱ, ⅲ, avr, avl, avf,v1~v6, gnd
s-t segment analysis: -2.0~2.0mv
arrhythmia analysis: yes
protection: with stand 4000vac/50hzvoltage in isolation and work against electrosurgical knife and defibrillation
respiration
measurementmethod: thoracic impedance
standardparameter & configuration
 ecg/resp/defibrillator
optionalparameter
recorder