- 测量行程:3500(mm)
- 机台尺寸:L920mm x W620mm x H900mm+120mm(mm)
加工定制 否 品牌 韩国jiinpoong 型号 tc-15
测量范围 w180mm x l530mm 磨擦频率 w180mm x l530mm 测量行程 3500(mm)
机台尺寸 l920mm x w620mm x h900mm+120mm(mm)
<inputid=offer_video_refkey value=offer-1269692910 type=hidden/>
韩国振动机抛光机此款机器三星,lg等一系列手机电子厂的喷涂工艺检测.检测手机电池背盖,手机按键.手机导航件.手写笔.听筒丝网.手机框.等一系列喷涂所需检测。
韩国振动机抛光机 的详细介绍
产品名称:韩国振动抛光机
详细介绍:韩国振动机抛光机韩国振动机抛光机
first of all, thank you for buying one of ourmachines.
we are producing vibratory finishingmachines, vibration applied machines, precision processing specialmachines with our accumulated technology and thorough qualitysystems under our motto that we serve our customers with the bestquality products
.
we would like to introduce, through this manual, how to properlyuse the machine, to perform its best function in operation that ourdevelopment and production team have made with theirendeavors.
this manual will guide the users to understand the equipment, howto use in the best conditions, how to increase productivity, how tomaintain the equipment in the very simple way.
foranything that is not sufficiently described, please feel free tocontact our office, then we will supply with further informationthat we can do.
we hope this equipment will do a goodrole in your business, good luck!
fromall the members of jin poong b.r. tech.
warranty
1.warraty period of this equipment is 1 year or2000 hours whichever comes first. and warranty period of theelectrical parts is 6 months.
this is based on the normal operation,operator’s mistakeor mishandling of the equipment, excessive operation beyond itscapability and failure to maintain on time will release thewarranty obligation.
2. inany case that the user has changed the machine parts or correctedwithout any prior agreement, this warranty will beinvalid..
painting durability tester machine
model : tc - 15 (sm - 1502)
i. composition of the equipment
1.vibratory tumbler
2. soundcover
3. autowater & compound supply system
4.control unit
ii. specification of theequipment
1. vibratory tumbler
tub interior dimension: w180mmx l530mm
in-put area dimension: w130mm x l530mm
lining : hot pour polyurethanecasting, thickness: 15mm
motor : 220v x 1hp x 3ph x60hz. (2 pole)
motor r.p.m : 3500
2.sound cover
l920mm x w620mm xh900mm+120mm
top door with gascylinder
3. autowater & compound supply system
water tank, metered to be500ml
water tank, metered to be 1000ml +addition of compound 200ml
water tank, metered to be 500ml +addition of compound 20ml
compound metering pump 300ml/min,adjusted to supply 200 ml by a timer.
compound metering pump 20ml/min,adjusted to supply 20 ml by a timer.
iii.utility requirement
1 electrical power: 220vx 1ph (20a).
2 tap water: 4l/hr. (tobe linked to the right side of the control unitby 8mm hose.)
iv.installation
just place onthe flat concrete floor without any anchoring.
in casethe equipment is not horizontally leveled, the mass in the tumblercan move to a side,
pleasebe careful.
please link 3 wires from the motor to the u.v.w. terminal in thecontrol box.
please link 2 wires from the mainsource of electrical power to the r.t. terminal in thebox.
please link tap water to the supply valve on the right side of thecontrol box by 8mm hose.
in case tap water contains some foreign substance, please installpre-filter before this hose.
please link a hose(20mm) from thehose nipple on left side of the control box to the mainmachine.
a little longer hose is shipped with machine, please cut it off andadjust depending on
the siteallocation
. please link the discharge valve on the rear side of machine to thelaboratory discharge pipe line.
please leave the dischargevalve always open except for the maintenance.
a compoundcontainer needs to be placed in the room under the controlbox.
please remove the top lid and place the container in the room andput a separate lid pre-drilled
on 3places, 1 big hole in the center and 2 small holes on the right andleft.
on the center hole, please place a level sensor which emit alarmwhen there is not enough
compoundin the container,
and onthe right and left holes insert 2 hoses that come from the meteringpumps.
v.operation
supply the control box with power(put the breaker switch on, put the disconnect switch on)and
put theselector switch on, then you will have light on the powerlamp.
fill the vibratory tumbler with media 15l(11.25l of cone and 3.75l of pyramid).
put themode to manu and push on start.
if themass turns from front to back, the motor direction iscorrect.
in caseit turns in the opposite direction please correct by changing thewire.
1. preparation course
themedia contains some flashes and burrs. this course is, prior to themain course of testing,
tocondition the media by tumbling to the right purpose of thetesting.
firstof all, put mode to manu and push on pre water-1, then 500ml tankwill be filled with water.
pls push on only once, if you push on twice it will bestopped.
o once it is full, it will be automatically disconnected. when thewater is evacuated, the tank
isautomatically refilled, therefore from next time, there is no needto put to manu and fill again.
.
set the timer 4 hours or 10 hours as required by your company(currently designated to be 10 hours).
put mode to pre and push on start then thetumbler will start to run and 2000 ml of water
will besupplied automatically.(4 times of 500ml)
at thetime of start, 2000ml will be supplied and 500ml will be suppliedevery 30 min. automatically.
the tank always keeps water 500ml. and supplies when it isrequired.
2. maincourse of testing
thiscourse is to test whether the testing parts are safe or damagedwhen the media and parts
haverubbed each other in the vibratory tumbler.
first ofall, put mode to manu and push on main water-1, then water will beready with 1000ml
in thetank 1, push on main water-2 then water will be ready with 500ml inthe tank 2.
push on comp-1, then 200ml of compound will be added to 1000ml ofwater in the tank-1.
push on comp-2, then 20ml of compound will be added to 500ml ofwater in the tank-2.
pls push on only once, if you push on twice it will bestopped.
once you have filled for the first time, when the liquid isevacuated, it is made again automatically
therefore there is no need to do manuallyagain.
set the timer 1 hour or 2 hours as required by yourcompany.
put the mode to manu and start the machine, then 1000mml of waterand 200ml of compound
will beautomatically supplied in the beginning and 500ml of water and 20mlof compound
will besupplied every 30 min.
(note) when there is not enough compound,you will have alarm light on the control panel,
pleasefill the container with compound.
vi.maintenance
in case the inverter inside the control box repeats to trip,one of the 3 wires from the motor
mighthave been disconnected by the vibration. please take out thevibratory tumbler from the
soundproof box and disassemble the drain pipe lines and lift up the tuband check the wires
from themotor. if any of the wires were disconnected, please correctit.
in casethere is any loud noise from the vibratory tumbler, the bearings onthe motor must have
broken,please replace them referring to the assembly drawing of themotor.
in casethe liquid of water and compound is not supplied well, some foreignsubstance might have
beenstuck in the ball, please clean the valve referring to the separatemanual.
incase compound is not well injected from the metering pump, pleaseclean the balls on the
suctionand discharge port of the diaphragm pump.
(referring to the separate manual, pls clean partno. 2,3,4.)
this mayhappen after long holidays.
pleaseclean the filter that is installed right after the in-put watervalve on the right side of
thecontrol box.
vii.warranty & free replacement
we warrant quality for either 380days from the date of shipment or 2000 hours ofoperation,
whichever comes first. in case any part does notwork properly, we send replacement part only.
加工定制 否 品牌 韩国jiinpoong 型号 tc-15
测量范围 w180mm x l530mm 磨擦频率 w180mm x l530mm 测量行程 3500(mm)
机台尺寸 l920mm x w620mm x h900mm+120mm(mm)
<inputid=offer_video_refkey value=offer-1269692910 type=hidden/>
韩国振动机抛光机此款机器三星,lg等一系列手机电子厂的喷涂工艺检测.检测手机电池背盖,手机按键.手机导航件.手写笔.听筒丝网.手机框.等一系列喷涂所需检测。
韩国振动机抛光机 的详细介绍
产品名称:韩国振动抛光机
详细介绍:韩国振动机抛光机韩国振动机抛光机
first of all, thank you for buying one of ourmachines.
we are producing vibratory finishingmachines, vibration applied machines, precision processing specialmachines with our accumulated technology and thorough qualitysystems under our motto that we serve our customers with the bestquality products
.
we would like to introduce, through this manual, how to properlyuse the machine, to perform its best function in operation that ourdevelopment and production team have made with theirendeavors.
this manual will guide the users to understand the equipment, howto use in the best conditions, how to increase productivity, how tomaintain the equipment in the very simple way.
foranything that is not sufficiently described, please feel free tocontact our office, then we will supply with further informationthat we can do.
we hope this equipment will do a goodrole in your business, good luck!
fromall the members of jin poong b.r. tech.
warranty
1.warraty period of this equipment is 1 year or2000 hours whichever comes first. and warranty period of theelectrical parts is 6 months.
this is based on the normal operation,operator’s mistakeor mishandling of the equipment, excessive operation beyond itscapability and failure to maintain on time will release thewarranty obligation.
2. inany case that the user has changed the machine parts or correctedwithout any prior agreement, this warranty will beinvalid..
painting durability tester machine
model : tc - 15 (sm - 1502)
i. composition of the equipment
1.vibratory tumbler
2. soundcover
3. autowater & compound supply system
4.control unit
ii. specification of theequipment
1. vibratory tumbler
tub interior dimension: w180mmx l530mm
in-put area dimension: w130mm x l530mm
lining : hot pour polyurethanecasting, thickness: 15mm
motor : 220v x 1hp x 3ph x60hz. (2 pole)
motor r.p.m : 3500
2.sound cover
l920mm x w620mm xh900mm+120mm
top door with gascylinder
3. autowater & compound supply system
water tank, metered to be500ml
water tank, metered to be 1000ml +addition of compound 200ml
water tank, metered to be 500ml +addition of compound 20ml
compound metering pump 300ml/min,adjusted to supply 200 ml by a timer.
compound metering pump 20ml/min,adjusted to supply 20 ml by a timer.
iii.utility requirement
1 electrical power: 220vx 1ph (20a).
2 tap water: 4l/hr. (tobe linked to the right side of the control unitby 8mm hose.)
iv.installation
just place onthe flat concrete floor without any anchoring.
in casethe equipment is not horizontally leveled, the mass in the tumblercan move to a side,
pleasebe careful.
please link 3 wires from the motor to the u.v.w. terminal in thecontrol box.
please link 2 wires from the mainsource of electrical power to the r.t. terminal in thebox.
please link tap water to the supply valve on the right side of thecontrol box by 8mm hose.
in case tap water contains some foreign substance, please installpre-filter before this hose.
please link a hose(20mm) from thehose nipple on left side of the control box to the mainmachine.
a little longer hose is shipped with machine, please cut it off andadjust depending on
the siteallocation
. please link the discharge valve on the rear side of machine to thelaboratory discharge pipe line.
please leave the dischargevalve always open except for the maintenance.
a compoundcontainer needs to be placed in the room under the controlbox.
please remove the top lid and place the container in the room andput a separate lid pre-drilled
on 3places, 1 big hole in the center and 2 small holes on the right andleft.
on the center hole, please place a level sensor which emit alarmwhen there is not enough
compoundin the container,
and onthe right and left holes insert 2 hoses that come from the meteringpumps.
v.operation
supply the control box with power(put the breaker switch on, put the disconnect switch on)and
put theselector switch on, then you will have light on the powerlamp.
fill the vibratory tumbler with media 15l(11.25l of cone and 3.75l of pyramid).
put themode to manu and push on start.
if themass turns from front to back, the motor direction iscorrect.
in caseit turns in the opposite direction please correct by changing thewire.
1. preparation course
themedia contains some flashes and burrs. this course is, prior to themain course of testing,
tocondition the media by tumbling to the right purpose of thetesting.
firstof all, put mode to manu and push on pre water-1, then 500ml tankwill be filled with water.
pls push on only once, if you push on twice it will bestopped.
o once it is full, it will be automatically disconnected. when thewater is evacuated, the tank
isautomatically refilled, therefore from next time, there is no needto put to manu and fill again.
.
set the timer 4 hours or 10 hours as required by your company(currently designated to be 10 hours).
put mode to pre and push on start then thetumbler will start to run and 2000 ml of water
will besupplied automatically.(4 times of 500ml)
at thetime of start, 2000ml will be supplied and 500ml will be suppliedevery 30 min. automatically.
the tank always keeps water 500ml. and supplies when it isrequired.
2. maincourse of testing
thiscourse is to test whether the testing parts are safe or damagedwhen the media and parts
haverubbed each other in the vibratory tumbler.
first ofall, put mode to manu and push on main water-1, then water will beready with 1000ml
in thetank 1, push on main water-2 then water will be ready with 500ml inthe tank 2.
push on comp-1, then 200ml of compound will be added to 1000ml ofwater in the tank-1.
push on comp-2, then 20ml of compound will be added to 500ml ofwater in the tank-2.
pls push on only once, if you push on twice it will bestopped.
once you have filled for the first time, when the liquid isevacuated, it is made again automatically
therefore there is no need to do manuallyagain.
set the timer 1 hour or 2 hours as required by yourcompany.
put the mode to manu and start the machine, then 1000mml of waterand 200ml of compound
will beautomatically supplied in the beginning and 500ml of water and 20mlof compound
will besupplied every 30 min.
(note) when there is not enough compound,you will have alarm light on the control panel,
pleasefill the container with compound.
vi.maintenance
in case the inverter inside the control box repeats to trip,one of the 3 wires from the motor
mighthave been disconnected by the vibration. please take out thevibratory tumbler from the
soundproof box and disassemble the drain pipe lines and lift up the tuband check the wires
from themotor. if any of the wires were disconnected, please correctit.
in casethere is any loud noise from the vibratory tumbler, the bearings onthe motor must have
broken,please replace them referring to the assembly drawing of themotor.
in casethe liquid of water and compound is not supplied well, some foreignsubstance might have
beenstuck in the ball, please clean the valve referring to the separatemanual.
incase compound is not well injected from the metering pump, pleaseclean the balls on the
suctionand discharge port of the diaphragm pump.
(referring to the separate manual, pls clean partno. 2,3,4.)
this mayhappen after long holidays.
pleaseclean the filter that is installed right after the in-put watervalve on the right side of
thecontrol box.
vii.warranty & free replacement
we warrant quality for either 380days from the date of shipment or 2000 hours ofoperation,
whichever comes first. in case any part does notwork properly, we send replacement part only.
深圳欧普瑞检测设备有限公司