1u single】p1u-6200p
200w
server ,workstation ,storage system ,ipc
190x100x40(mm)
7.48x3.94x1.57(inch)
voltage: 90 ~ 264 vac full range
frequency : 47 ~ 63 hz
input current: 4.0 a ( rms ) for 110vac
2.0 a ( rms ) for 220vac
inrush current: 65 a max. for 110 vac
130 a max. for 220 vac
output voltage output current min. output current max. regulation load regulation line output ripple & noise max.[p-p]
5v 2 16 ± 5% ± 1% 70mv
12v 1 7 ± 5% ± 1% 120mv
-5v 0.1 0.2 ± 5% ± 1% 100mv
-12v 0.1 0.7 -10%~+10% ± 1% 120mv
3.3v 1 14 ± 5% ± 1% 70mv
+5vsb 0.1 1.5 ± 5% ± 1% 70mv
remarks: 1. the output power of 5v & 3.3v not exceed 110 watts 2. total output power not exceed 200 watts
*active pfc (full range), meet iec-1000-3-2 class d
*12v max. current : 9a
*temperature range: operating 0℃ ~ 40℃.
* humidity:operating:20%-95%, non-operating:10%-95%
* remarks:85% is normal condition and 95% is with special coating process
*emi noise filter: fcc class b, cispr22 class b
*over power protection
*over voltage protection
*short circuit protection
*safety: ul, csa, tuv, ccc, gost
*remote on/off control
*cooling: two 40 mm nmb ball bearing dc fans
*3.3v /5v remote sensing
*serial ata optional
*the power-supply is for chassis-assembly only and is not allowed to be operated as stand-alone component. final assembly has to comply with corresponding emc- and safety-regulations.