您好,欢迎来到三六零分类信息网!老站,搜索引擎当天收录,欢迎发信息

6050咪头厂家供应环保焊线咪头

2018/8/1 10:08:47发布106次查看
加工定制品牌TLS
型号6050咪头种类传声器(咪头)
类型驻极体传声器材质铝镁合金
规格尺寸6.0*5.0mm声道数多声道
灵敏度-42dB频率响应20-20khz
输出阻抗2.2k

降噪咪头厂商_蓝牙咪头生产商_全指向咪头生产厂家
深圳市泰伦斯电子有限公司成立于2012年,是一家集研发、生产、销售服务于一体,以生产咪头及电声产品为主的企业。 公司注册资本50万元,现有员工30多人,累积投资近1000万,拥有10多套自动化生产线。在设计及研发技术方面,处于行业领先水平,拥有多名半导体技术的行业专家及复合型技术管理人才,自主研发能力及创新能力位于业界同行前列,积极创新,吸收业界***前沿的技术资源。 公司具有严谨的品质管理体系,具备电子应用产品自配套能力强的优势,公司的产品整核了公司系列产品的优势,使顾客能用普通的价格享受到高端品质。(1) vibration test振动试验
to be no interference in operation after vibrations, 10hz to 50hz for 2 ho-urs full amplitude 1.52mm ,the sensitivity to be within ±3db from initial sens-itivity,the measurement should be done  after 3 hours at the room temperature.
将没有操作干扰过的咪头,在10hz到50hz、1.52 mm全振幅下振动 30分钟后,试验后在常温下放置3小时后测试,灵敏度变化在±3db内。
(2) dro test跌落试验 
the microphone without packaged must be subjected to each 3 drops at three axises from the  height of 120cm to 2cm thick hardwood board, the sensitivity to be within ±3db from initial sensitivity,the measurement should be done  after 3 hours at the room temperature.
不带包装的咪头经过从3个不同的轴面从120厘米的高度下落到2厘米厚的硬质木板上,试验后在常温下放置3小时后测试,灵敏度变化在±3db内。
(3) high temperature test高温试验
to be no interference in operation after high temperature test 70±3℃ for 48 hours. the sensitivity to be within ±3db from initial sensitivity, the mea-surement should be done  after 3 hours at the room temperature.
将没有操作干扰过的咪头在70±3℃高温下试验48小时,试验后在常温下放置3小时后测试,灵敏度变化在±3db内。
(4) isotherm & iso-humidity test恒温恒湿试验
to be no interference in operation after storage test at temperature 55±3℃ and relative humidity (95±3%) for 48 hours, the sensitivity to be within ±3db from initial sensitivity, the measurement should be done  after 3 hours at   the room temperature.
将没有操作干扰过的咪头在温度55±3℃、相对湿度95±3%的环境下试验48小时,试验后在常温下放置3小时后测试,灵敏度变化在±3db内 。
(5) low temperature test 低温试验
to be no interference in operation after low temperature test -25±3℃ for 48 hours, the sensitivity to be within ±3db from initial sensitivity,the meas-urement should be done  after 3 hours at the room temperature.
将没有操作干扰过的咪头在-25±3℃的低温环境下放置48小时,试验后在常温下放置3小时后测试,灵敏度变化在±3db内 。
(6) temperature cycle test温度循环试验 
to be no interference in operation after expos